Solutions: PowerScout

Electrical Load Profiling

Measurement & Verification

Energy Audits
DENT PowerScout HD Meters are available in four channel count options: 3, 12, 24, and 48 channels. Designed for flexibility and accuracy, these meters are certified for top-notch performance, making them perfect for a variety of applications, from residential and commercial spaces to retail and utilities.
Jump down to see an at-a-glance comparison table for all PowerScout HD meters, highlighting key features and specifications to help you choose the right solution for your needs.
Connect to Any Endpoint
Seamlessly connect to any endpoint with DENT PowerScout HD Meters, offering unparalleled flexibility and integration capabilities. Whether you’re monitoring energy consumption in a residential complex, managing power usage in a commercial building, or optimizing performance in a retail environment, our meters are designed to interface with a wide range of systems and devices. Equipped with advanced communication protocols and customizable options, DENT PowerScout HD Meters ensure reliable data transmission and real-time insights, making it easier than ever to achieve your energy management goals.
The PowerScout HD Lineup

Single Channel Meter
PowerScout 3HD
DENT’s PowerScout3 HD meter offers increased measurement performance and communication options in a single SKU. It can utilize any of DENT’s internally shunted, 333.3mV output split-core, solid core, or RoCoil CTs. Monitor a single three phase load or network with other PowerScout HD meters to monitor several loads across your facility.

Multi-Channel Meter
PowerScout 12HD
The PowerScout 12 HD is a versatile, multi-channel instrument. The flexible design allows it to be configured for monitoring multiple electrical circuits. It can be supplied with any of DENT’s internally-shunted, 333 mV output split-core, solid core, or RōCoil CTs. Monitor any combination of up to 4 three-phase or 12 single-phase electrical devices with a single PowerScout HD. The PowerScout 12 HD is well-suited for data center monitoring, tenant submetering, and for accountability metering in commercial, retail, and industrial facilities.

Multi-Channel Meter
PowerScout 24HD
The PowerScout 24 HD is a versatile, multi-channel instrument. The flexible design allows it to be configured for monitoring multiple electrical circuits. Designed specifically for applications where 12 channels are not enough, but 48 channels are overkill, the just-right PowerScout 24 HD can be supplied with any of DENT’s internally-shunted, 333 mV output split-core, solid core, or RōCoil CTs. Monitor any combination of up to 8 three-phase or 24 single-phase electrical devices with a single meter. The PowerScout 24 HD is well-suited for data center monitoring, tenant submetering, and for accountability metering in commercial, retail, and industrial facilities.

Multi-Channel Meter
PowerScout 48HD
The PowerScout 48 HD is a versatile, multi-channel instrument. The flexible design allows it to be configured for monitoring multiple electrical circuits. It can be supplied with any of DENT’s internally-shunted, 333 mV output split-core, solid core, or RōCoil CTs. Monitor any combination of up to 16 three-phase or 48 single-phase electrical devices with a single PowerScout HD. The PowerScout 48 HD is well-suited for data center monitoring, tenant submetering, and for accountability metering in commercial, retail, and industrial facilities.
Product Comparison Chart
![]() PowerScout 3HD |
![]() PowerScout 12HD |
![]() PowerScout 24HD |
![]() PowerScout 48HD |
|
---|---|---|---|---|
Current Channels | 3 channels, 0.525 VAC max, 333 mV CTs, Rogowski CTs | 12 channels, 0.525 VAC max, 333 mV CTs, Rogowski CTs | 24 channels, 0.525 VAC max, 333 mV CTs, Rogowski CTs | 48 channels, 0.525 VAC max, 333 mV CTs, Rogowski CTs |
Phasing/Wiring | Single Phase, Three Phase-Four Wire (WYE), Three Phase-Three Wire (Delta) | Single Phase, Split Phase, Three Phase-Four Wire (WYE), Three Phase-Three Wire (Delta) | Single Phase, Split Phase, Three Phase-Four Wire (WYE), Three Phase-Three Wire (Delta) | Single Phase, Split Phase, Three Phase-Four Wire (WYE), Three Phase-Three Wire (Delta) |
Voltage Configurations | 80-346 Volts AC Line-to-Neutral, 600 V Line-to-Line, CAT III | 90-346 Volts AC Line-to-Neutral, 600V Line-to-Line, CAT III | 90-346 Volts AC Line-to-Neutral, 600V Line-to-Line, CAT III | 90-346 Volts AC Line-to-Neutral, 600V Line-to-Line, CAT III |
Voltage Channels | 1x Three-Phase Voltage Reference Input | 1x Three-Phase Voltage Reference Input | 2x Three-Phase Voltage Reference Input | 2x Three-Phase Voltage Reference Input |
Max Current | None. Accepts up to 150% of 333.3mV CT rating or 4000A with a RoCoil CT | None. Accepts up to 150% of 333.3mV CT rating or 4000A with a RoCoil CT | None. Accepts up to 150% of 333.3mV CT rating or 4000A with a RoCoil CT | None. Accepts up to 150% of 333.3mV CT rating or 4000A with a RoCoil CT |
Pulse Inputs | N/A | Four (4x) inputs. 3.3V sourcing voltage (current limited) to customer dry contact pulse output. Max pulse rate 10 Hz (50 mSec minimum transition time) | Two (2x) inputs. 3.3V sourcing voltage (current limited) to customer dry contact pulse output. Max pulse rate 10 Hz (50 mSec minimum transition time) | Two (2x) inputs. 3.3V sourcing voltage (current limited) to customer dry contact pulse output. Max pulse rate 10 Hz (50 mSec minimum transition time) |
Communications Protocol | Standard: Modbus RTU, BACnet MS/TP,Modbus TCP or BACnet IP | Standard: Modbus RTU, BACnet MS/TP, Modbus TCP or BACnet IP | Standard: Modbus RTU, BACnet MS/TP, Modbus TCP or BACnet IP | Standard: Modbus RTU, BACnet MS/TP, Modbus TCP or BACnet IP |
Current Transformer Options | Split Core, Solid Core, Rogowski Coil | Split Core, Solid Core, Rogowski Coil | Split Core, Solid Core, Rogowski Coil | Split Core, Solid Core, Rogowski Coil |
Enclosure Options | Wall Mount, Rail Mount | Enclosure, Plate | Enclosure, Plate | Enclosure, Plate |
Accuracy | 0.2% ANSI C12.20-2015 Class 0.2 | 0.2% ANSI C12.20-2015 Class 0.2 | 0.2% ANSI C12.20-2015 Class 0.2 | 0.2% ANSI C12.20-2015 Class 0.2 |
Configurations | 3PH: x1 2PH: x1 1PH: x1 |
3PH: 4×3 2PH: 4×2* 1PH: 12×1 |
3PH: 8×3 2PH: 8×2* 1PH: 24×1 |
3PH: 16×3 2PH: 16×2* 1PH: 48×1 |
Cloud Compatibility | Yes | Yes | Yes | Yes |
API Capable | Yes | Yes | Yes | Yes |
Certifications | UL 61010 Listed CE RoHS |
Plate: UL Recognized 61010 Enclosure: UL Listed 61010 CE RoHS |
Plate: UL Recognized 61010 Enclosure: UL Listed 61010 CE RoHS |
Plate: UL Recognized 61010 Enclosure: UL Listed 61010 CE RoHS |
Compliance | CTEP NYC Local Law 88 |
CTEP NYC Local Law 88 |
CTEP NYC Local Law 88 |
CTEP NYC Local Law 88 NY PSC |
*Virtual Element capability coming soon